Description
100% tested before shipping in accordance with ISO 15738.
Production test tollerances -5 +10% - Functional tollerances for user -5 +20%
INSTALLATION
1a. HOLE REQUIRED FOR RV70 VALVE INSTALLATION = D70 +/-0,5 mm
1b. HOLE REQUIRED FOR RVG70 VALVE INSTALLATION = D41 +/-0,5 mm
2. TIGHTENING TORQUE = 30 Nm
THE VALVE ASSEMBLY SHOULD BE RE-TORQUED AFTER AT LEAST 12 HOURS
3. THE USERS RESPONSIBILITY TO ENSOURE THAT ANY FLUIDS USED DURING THE
INSTALLATION OR OPERATION ARE COMPATIBLE WITH THIS VALVE
4. PRESSURES SETTING AVAILABLE IN THE TABLE ATTACHED
Item | Part number | Calibration | Color | Opening | Closing | ||||
Pax 1000 | mbar | psi | Pax 1000 | mbar | psi | ||||
VA | KA080173 | 180/150 | Rosso/Red | 18.0 | 180 | 2.6 | 15.0 | 150 | 2.2 |
KA080174 | 200/170 | Nero/Black | 20.0 | 200 | 2.9 | 17.0 | 170 | 2.5 | |
KA080175 | 230/200 | Grigio/Grey | 23.0 | 230 | 3.3 | 20.0 | 200 | 2.9 | |
KA080176 | 255/225 | Verde/Green | 25.5 | 255 | 3.7 | 22.5 | 225 | 3.3 | |
KA080177 | 280/250 | Blu/Blue | 28.0 | 280 | 4.0 | 25.0 | 250 | 3.6 |